Analog-way Eikos - EKS500 Programmer's Guide Instrukcja Użytkownika Strona 14

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 55
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 13
14
Group Name CmdResp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_INVERT KI KI Invert keying area Rd/Wr 0 1 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_GRAB_ENABLE Kg Kg
Enable/disable the keying color
grabber mode
Rd/Wr 0 1 0
0 = Disable the grabber
1 = Enable the grabber
IN_KEYING_GRAB_GET Kc Kc
Capture the coolor selected by
the grabber and apply the
settings
Rd/Wr 0 1 0
Percent of
OSCREEN_UTIL_H
IN_KEYING_GRAB_H Kh Kh
Horizontal position of the
grabber
Rd/Wr 0 65535
32768
Precent of
OSCREEN_UTIL_V
IN_KEYING_GRAB_V Kv Kv Vertical position of the grabber
Rd/Wr 0 65535
32768
INPUT
STATUS
SIG_HPOL sh sh Input H sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_VPOL sv sv Input V sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
Przeglądanie stron 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 54 55

Komentarze do niniejszej Instrukcji

Brak uwag