Analog-way Eikos - EKS500 Programmer's Guide Instrukcja Użytkownika Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 55
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
12
Group Name CmdResp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
cable length
1 = 5 to 20 meters cable
length
2 = More than 15 meters
cable length
11 = Input12
KEYING
IN_KEYING_TYPE KT KT Keying type Rd/Wr 0 4 0
0 = No keying
1 = Luma Key Keying
2 = ChromaKey Keying
3 = Luma Key Keying + DSK
4 = ChromaKey Keying +
DSK
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_R_LEVEL KR KR Keying level (Red ) Rd/Wr 0 255 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_G_LEVEL KG KG Keying level (Green) Rd/Wr 0 255 255
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_B_LEVEL KB KB Keying level (Bule) Rd/Wr 0 255 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
Przeglądanie stron 11