72
7.3.17 Control management
Auto Calibrate
Click on start to launch an auto calibraon of colors, on your analog input/output chips. (See chapter: 11.
Maintenance and support)
Erase memories
Into this secon, you can erase individual sengs.
• Erase input sengs memory: All input sengs will return to
their default value. This includes image, aspect, user format
and keying parameters.
• Erase preset memories: All preset memories will return to
their default value.
• Erase monitoring layout memories: all saved monitoring
layout conguraon will be erased, the monitoring layout will
be the default one.
• Erase library logos: All saved logos and frames will be deleted
from the library that can contain up to 100 sll pictures.
• Erase library EDIDS: All EDIDs saved on the library free slots
will be deleted.
• Erase library sequencer: all sequences saved on the sequencer
library will be deleted.
Factory reset
click on START to
reset all standard parameters of your device to
default sengs.
• This seng does not reset the network/link
sengs.
• Library frames and logos will not be erased,
the device will reboot aer this operaon.
click on START
to reset all use parameters of your device to
default. Aer reboong, you will nd your unit
in the same state as when you opened the box
for the rst me.
• This operaon will erase all libraries including the frames and logos library images.
• The device will reboot aer this operaon.
• This operaon can also be found in the front panel.