26
Group Name CmdResp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SET_RESET_SETTINGS Ss Ss Current input default settings Rd/Wr
0 1 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_FREEZE Sf Sf Freeze of the input Rd/Wr
0 1 0 1 = Freeze
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_MOTION_DETECT Sm Sm
0 : max correction; 15 : min
correction
Rd/Wr
0 15 15
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
Przeglądanie stron 25